- Industrial Cables
- Le nostre soluzioni
- Azienda
- Stampa
- Strumenti e risorse
- Career
- Cerca su
- Contattaci
- Confronta
- Accedi
DR 6
Descrizione
Descrizione
Norme
-
ProductEN 2267-010
DESIGN CONSTRUCTION
CORE
Stranded Conductor : Nickel Plated High
Strength Copper Alloy (AWG 26 & 24) or
Nickel Plated Copper (AWG 22 to 2)
INSULATION
Special Polyimide Tape
Special UV PTFE Tape(s)
IDENTIFICATION
Standard colour code :
White except AWG 26 which is light yellow and AWG 22 which is light green
AWG 24 is available in light blue color (EN2267-010A 002B)
Color of marking: green
Marking text: EN DR ** FR F ++
DR = Short designation
** = AWG Wire Size
FR = Country of origin (FR = France)
F = Manufacturer (F = Lynxeo)
++ = Year of production (i.e. 13 = 2013)
ELECTRICAL AND HIGH FREQUENCY PERFORMANCES
Voltage rating: 600 Volts RMS at sea level,
Usual Aerospace application are using 115 Volts (Phase to Neutral)
and 200 Volts (Phase to Phase) 400Hz AC or 28 Volts DC.
Maximum operating frequency: 2000Hz